Puno Filter / Quality and documents
Quality and documents
What is checked before a cartridge ships, and the paperwork you can ask for to put in your own or your customer's file.
Documents you can ask for
| Document | What it shows | Status |
|---|---|---|
| Integrity-test record | Bubble point, diffusion flow or water intrusion result for the cartridge | Ask with your order |
| Batch record and serial number | Traceability of a sterilizing-grade cartridge to its production batch | Ask with your order |
| Bacterial retention report | Third-party challenge test on sterilizing PTFE cartridges | Held by the factory; on request |
| Steam-sterilization report | Resistance of 0.2 micron PES cartridges to repeated steaming | Held by the factory; on request |
| Extractables and biosafety reports | What can migrate from the cartridge; plastics safety testing | Held by the factory; on request |
| SGS material reports | Material tests for polypropylene, PTFE and nylon cartridges | Held by the factory; on request |
| Material statement | Which membrane and resin a cartridge is made from | Ask us |

What is tested
- Every absolute-rated cartridge is integrity tested before it ships.
- Sterilizing-grade cartridges are individually numbered, with batch records.
- Capsule filters are also flushed with pure water and pressure tested.
- The first cartridges of each run are approved before the batch continues.
How a cartridge is made
- Incoming membrane and resin are inspected.
- The membrane is pleated with its support layers and cut to length.
- The seam is welded, then the end caps are welded on. No adhesive is used.
- The semi-finished cartridge is tested.
- It is flushed, dried, given its end fittings and vacuum packed.
- It is inspected again before dispatch.
Production runs in a class 10,000 cleanroom. Cartridges for electronics are flushed with 18 megohm ultrapure water; pharmaceutical-grade cartridges with two-pass reverse-osmosis water.
Materials
Membranes are bought from established makers in Germany, the United States, Japan and Italy. Materials for pharmaceutical and food cartridges are chosen to meet FDA requirements and USP Class VI plastics testing.
Validation support
For sterile-filtered products, the factory's laboratory can run the studies a filter validation needs: bacterial viability in your liquid, product-wetted integrity limits, chemical compatibility, bacterial challenge on three lots to ASTM F838, extractables and adsorption.
Request a quote
The more you can tell us about the duty, the closer the first quote will be. A photo or model number of your current cartridge is enough to start.