Cartridge filters in a purified water system

A purified water system uses cartridge filters in three places: a 5 micron polypropylene cartridge ahead of the reverse osmosis membranes, a 0.2 micron membrane cartridge after treatment, and a hydrophobic vent filter on the storage tank.

Where the cartridges sit

PositionJobTypical cartridgeTypical rating
After the sand and carbon filters, ahead of reverse osmosisStops sand, carbon fines and scale from reaching the reverse osmosis membranesPolypropylene, pleated or melt-blown5 micron; 1 micron where the feed is clean
After reverse osmosis, deionization and ultraviolet treatmentRemoves particles and bacteria shed by the equipment upstreamPES membrane0.2 micron; 0.1 micron for electronics-grade water
Storage tank ventLets the tank breathe as the level changes without drawing in airborne organismsHydrophobic PTFE0.2 micron
Point of useA last filter where the water is drawn offPES membrane cartridge or capsule0.2 micron

A typical layout. Systems for drinking water, pharmaceutical water and electronics water differ in the treatment steps between the cartridges.

A typical treatment line

Raw water, sand filter, carbon filter, softening or ion exchange, 5 micron cartridge, reverse osmosis (often two passes), electrodeionization, ultraviolet lamp, 0.2 micron cartridge, storage tank with a vent filter, then the points of use. Bottled-water lines are shorter and often use ozone in place of some steps.

Choosing the cartridge ahead of reverse osmosis

Choosing the final cartridge

PES is the usual choice because it wets with water and passes a high flow. For electronics water, cartridges are flushed with ultrapure water before they ship; ask for that when you order. For a small system or a single outlet, a capsule avoids installing a housing. See capsule versus cartridge.

For system builders

If you build water systems, we supply the cartridges and the stainless steel housings for 1 to 15 cartridges. Tell us the flow rate and the ratings and we will size it and send samples. Contact us.

Published . Last updated .

Request a quote

The more you can tell us about the duty, the closer the first quote will be. A photo or model number of your current cartridge is enough to start.