Puno Filter

Puno Filter / PVDF filter cartridges

PVDF filter cartridges

Pleated polyvinylidene fluoride (PVDF) membrane cartridges come in two types. Hydrophilic PVDF binds very little protein and is used for biological liquids; hydrophobic PVDF is used for gases and solvents.

Request samples or ask a question
PVDF membrane under an electron microscope

Specifications

MembranePolyvinylidene fluoride, hydrophilic or hydrophobic
Removal ratings0.2, 0.45, 1.0, 2.0, 3.0 and 5.0 micron
Filter areaAbout 0.6 m² per 10" single layer, 69 mm diameter
Operating limitUp to 90 °C; 0.42 MPa maximum differential at 25 °C
Steam sterilization121 °C for 30 minutes; more than 50 cycles
EndotoxinUnder 0.25 EU/ml
ExtractablesUnder 30 mg per 10" cartridge
Integrity testingEvery cartridge tested, individually numbered, with batch records
Lengths2.5", 5", 10", 20", 30" and 40"
Outer diameter69 mm standard; 83 mm and 130 mm available
End fittings226, 222 and 215, each with fin or flat end; double open end; stainless-lined 222 and 226
O-ringsSilicone, EPDM, NBR, fluoro rubber or fluoro-wrapped
ConstructionPolypropylene core, cage and supports; heat sealed, no adhesive

Figures are from the manufacturer's catalogue. Ask for the data sheet for the exact cartridge before you specify it.

Hydrophilic or hydrophobic

Hydrophilic PVDFHydrophobic PVDF
Use forHigh-protein solutions, culture media, drug-ingredient solutions, liquids with surfactantsSolvents, air and special gases
WettingWets with waterDoes not wet with water
Removal ratings0.2 to 5.0 micron0.2 to 5.0 micron
TemperatureUp to 90 °CUp to 90 °C
Steam121 °C for 30 minutes121 °C for 30 minutes

What it filters

What the manufacturer states

3D view

A PVDF cartridge with a fin end and a double O-ring fitting. The pleated membrane sits inside the cage. Drag to turn it. This is an illustration of the design, not a scale drawing.

Where it sits in the line

A PVDF cartridge is a final filter. Put a polypropylene prefilter ahead of it so the membrane only sees the fine particles.

See how ordering works.

Common questions

PVDF or PES for water-based liquids?

Both wet with water in their hydrophilic form. PES usually passes more flow and comes in more ratings, 0.04 to 10 micron. Hydrophilic PVDF is chosen where the lowest protein binding matters most, or where the liquid is warm or oxidising.

Do I need hydrophilic or hydrophobic PVDF?

Hydrophilic for water-based liquids. Hydrophobic for gases and for solvents; it does not wet with water.